Precautions For Selecting a Spray Pump For An Exhaust Gas Tow

TIME:2024-06-11 Author:admin Views:

What should you pay attention to when choosing a vertical pump for an exhaust tower?
1. Do not use a water pump with a mechanical shaft seal, because the water tank next to the exhaust tower is very small, and a water pump with a mechanical shaft seal is easily damaged by empty pumping, resulting in water leakage.

2. Do not use a magnetic pump, because the gap between the magnet inside the magnetic pump and the rear cover is very small, and the crystals in the medicine can easily rub against these two parts. Once worn out, the entire magnetic pump is equivalent to being scrapped.
 
 
3. the pump material engineering plastics anti-corrosion, because the working principle of acid mist, the requirements of the vertical pump will be added to the corrosive solution of the neutralization of the continuous cycle, at this time the pump material.
Must be corrosion-resistant materials, practice has shown that the corrosion resistance of engineering plastics is much better than metal materials!

4. the pump shall be used can be idling vertical pump, because the vertical pump can be no water idling, will not be damaged! Reduce unnecessary human damage, increase the stability of the equipment.

5. 4kW below the scrubber tower chemical pump is recommended to use in-slot vertical pumps, 4KW above the exhaust tower vertical pump is recommended to use outside the slot vertical pumps, do special placement of chemical pumps on the shelf, do not place the slot, because more than 4kW vertical pumps vibration in operation, over time, it is very easy to slot and the scrubber tower of the welding joints shock de-welding, resulting in leakage, which may cause the exhaust tower in serious cases of waste gas scrapped.