Acid and alkali resistant vertical pump is a kind of equipment commonly used in the chemical industry. It can handle corrosive liquids such as acid and alkali. During long-term use, due to aging or damage of components, it may need to be disassembled and repaired.

 
 
The following will introduce the disassembly and assembly steps of the acid-resistant vertical pump. First, before disassembly and assembly, you need to close the valves of the pump inlet and outlet pipes and cut off the power supply to ensure safe operation. Next, use a wrench to loosen the bolts next to the coupling and separate the coupling from the motor. Then, use a wrench to unscrew the flange cover bolts and separate the pump body from the pump seat. After disassembling the pump body, you can clean and repair it.
 
1. Use a detergent or solvent to clean the inner and outer surfaces of the pump body to remove dirt and accumulation. Then, check whether the impeller, shaft and bearing parts in the pump body are damaged, and replace or repair them if necessary. In addition, check the condition of the seals, and replace them if they are aged or worn.
 
2. After completing cleaning and repair, start assembly. First, reconnect the pump body to the pump seat, fix the bolts and tighten them with a wrench. Then, connect the coupling to the motor and tighten the bolts with a wrench. During the assembly process, you need to pay attention to the tightening force of the bolts, not too loose or too tight.
 
3. After the assembly is completed, the pump needs to be tested. First, check whether the various parts of the pump are installed correctly and tightened firmly. Then, open the valves of the inlet and outlet pipes, turn on the power, and start the motor. Observe the operation of the pump to ensure its normal operation.
 
4. After confirming that the vertical pump is operating normally, perform necessary maintenance work. Regularly check the pump's seals, bearings, lubricating oil and other components, and deal with any problems in time.
 
5. Regularly replace lubricating oil and seals to ensure long-term and stable operation of the pump.
 
6. The disassembly and assembly of the acid and alkali resistant pump requires caution and meticulousness, and the operator needs to have certain professional knowledge and skills. During the disassembly and assembly process, pay attention to safety and ensure correct operation.
 
7. Regular maintenance of the pump is the key to ensuring its normal operation. Only in this way can we give full play to the role of the acid and alkali resistant vertical pump and provide reliable support for the production of the chemical industry.